Sign In | Join Free | My xxjcy.com
China Guangdong ALI Testing Equipment Co,.Ltd logo
Guangdong ALI Testing Equipment Co,.Ltd
GSKA Group Specialized in kinds of PARTS since 1985, Developed and manufactured various generators and generator sets.
Active Member

13 Years

Home > Genset Diesel Generator >

50/100/500KW Convenient Silent Diesel Generator Set 120V/400V

Guangdong ALI Testing Equipment Co,.Ltd
Contact Now

50/100/500KW Convenient Silent Diesel Generator Set 120V/400V

  • 1
  • 2

Brand Name : GSKA

Model Number : Genset Diesel Generator

CertifiCAT-partsion : ISO9001

Place of Origin : China

MOQ : 1 unit

Price : Negotiable

Payment Terms : T/T L/C, 30% deposit,70% before delivery

Supply Ability : 100 units/ Per month

Delivery Time : 30 days

Packaging Details : Open type

Port : HongKong or ShenZhen,ShangHai,Dalian as required

Standby Power : 206/165 KVA/KW

Net Weigh (KGS) : 3250

Voltage Regulation : ±4%

Voltage : 400/230V

Alternator Model : Stamford or Leroy Somer

Coolant Volume (L) : 21.0

Starting Method : 12V DC electrical start

Speed : 1500rpm

Contact Now

50/100/500KW Convenient Silent Diesel Generator Set 120V/400V

 

Coordinated control of battery energy storage and diesel generator in independent AC microgrid


In the independent AC microgrid system, the coordination control between the diesel generator and the battery energy storage is the key to ensure the stable operation of the system. Based on the fast response characteristic of battery energy storage, a coordinated control method of diesel generator and energy storage battery was proposed. When the diesel generator is used as the main power supply, the auxiliary power control signal is introduced into the traditional droop control of the energy storage system to prevent the system collapse caused by the diesel engine overcurrent for a long time and improve the system stability. Aiming at the short-time power outage problem when the main power supply in the microgrid changes from the energy storage system to the diesel generator or from the diesel generator to the energy storage system, a seamless switching control strategy of the two main power supplies of the diesel generator and the energy storage battery is proposed.

 

 Modeling and operation simulation of Marine Diesel generator Set


The operation process of Marine diesel generator set is an important part of power plant operation. The number of diesel generators operating in parallel determines the capacity of a Marine power station. The stability of parallel operation is closely related to the stability of Marine power station. It is of great significance to establish a mathematical model which can accurately reflect the operation of diesel generator set for operation control, simulation and performance analysis of power station. The study of parallel operation of diesel generator sets involves the establishment of diesel generator model, parallel operation control model and electric load model. Although there are some different modeling methods for diesel generator model, most of them are limited to single model simulation. Taking diesel generator model as the core, the mathematical model of parallel operation of multiple diesel generator sets is established. Taking the "Yu-kun" ship power station as the reference object, the diesel generator model, power load model and parallel operation control system model are established respectively


The basic structure:


The basic structure of diesel generator is composed of diesel engine and generator. The diesel engine drives the generator to generate electricity.


The basic structure of diesel engine: cylinder, piston, cylinder head, inlet valve, exhaust valve, piston pin, connecting rod, crankshaft, bearing and flywheel components. Diesel generator diesel engine is generally single cylinder or multi cylinder four stroke diesel engine, I just talk about the basic principle of the work of single cylinder four stroke diesel engine: diesel engine starting is through manpower or other power to rotate the diesel crankshaft so that the piston in the top closed cylinder for up and down reciproCAT-parts-partsing motion. The piston completes four strokes in motion: the intake stroke, the compression stroke, the combustion and work (expansion) stroke and the exhaust stroke. When the piston moves from up to down, the inlet valve opens, and the fresh air filtered by the air filter enters the cylinder to complete the intake stroke. The piston moves upward from the bottom, the inlet and exhaust doors are closed, the air is compressed, the temperature and pressure increase, complete the compression process. When THE piston is about to reach the top, THE fuel INJECTOR will spray the filtered fuel into the combustion chamber in a mist and mix with the air of high temperature and pressure to burn on its own immediately. The high pressure will push the piston down to work, push the crankshaft to rotate and complete the work stroke. After the work stroke is finished, the piston moves up from the bottom, and the exhaust valve opens the exhaust to complete the exhaust stroke. The crankshaft rotates half a turn for each stroke. After several working cycles, the diesel engine gradually accelerates to work under the inertia of the flywheel.

 

Engine Data:

 

Manufacturer / Model:

DCEC Cummins 6CTA8.3-G2, 4-cycle 

Air Intake System:

Turbo, Water/Air Cooling 

Fuel System:

PB/W type fuel pump 

Cylinder Arrangement:

6 in line 

Displacement:

8.3L 

Bore and Stroke:

114*135(mm) 

Compression Ratio:

17:1 

Rated RPM:

1500rpm 

Max. Standby Power at Rated RPM:

180KW/244HP 

Governor Type:

Electronic 

Exhaust System 

Exhaust Gas Flow:

34.7m3/min 

Exhaust Temperature:

570℃ 

Max Back Pressure:

10kPa 

Air Intake System 

Max Intake Restriction:

6kPa 

Burning Capacity:

12.4m3/min 

Air Flow:

238m3/min 

Fuel System 

100%( Prime Power) Load:

215 g/Kw.h 

75%(Prime Power) Load:

211 g/Kw.h 

50%(Prime Power) Load::

216 g/Kw.h 

100%( Prime Power) Load:

39.7L /h 

Oil System 

Total Oil Capacity:

23.8L 

Oil Consumption:

≤4g/kwh 

Engine Oil Tank Capacity:

18.9L 

Oil Pressure at Rated RPM:

276-414kPa 

Cooling System 

Total Coolant Capacity:

34L 

Thermostat:

82-95℃ 

Max Water Temperature:

104℃ 

 

Alternator Data 

Number of Phase:

Connecting Type:

3 Phase and 4 Wires, “Y” type connecting 

Number of Bearing:

Power Factor:

0.8 

Protection Grade:

IP23 

Altitude:

≤1000m 

Exciter Type:

Brushless, self-exciting 

Insulation Class, Temperature Rise:

H/H 

Telephone Influence Factor (TIF):

<50 

THF:

<2% 

Voltage Regulation, Steady State:

≤±1% 

Alternator Capacity:

182KVA 

Alternator Efficiencies:

92.4% 

Air Cooling Flow:

0.514m3/s 

50/100/500KW Convenient Silent Diesel Generator Set 120V/400V

50/100/500KW Convenient Silent Diesel Generator Set 120V/400V50/100/500KW Convenient Silent Diesel Generator Set 120V/400V

 


Product Tags:

Silent Diesel Generator Set 120V

      

500KW Diesel Generator Set

      
Buy cheap 50/100/500KW Convenient Silent Diesel Generator Set 120V/400V product

50/100/500KW Convenient Silent Diesel Generator Set 120V/400V Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangdong ALI Testing Equipment Co,.Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)